Skip to content
01Services

Fire Detection & Alarm Systems

Supply, installation, commissioning and testing of conventional and addressable alarm systems.

At a glance

What it is
Supply, installation, commissioning and testing of conventional and addressable alarm systems.
Who it's for
New facilities that need a complete system before opening; Existing facilities with outdated or incomplete systems; Facilities expanding or changing activity and floor areas
What's included
Conventional alarm systems for small and mid-size facilities; Addressable systems that pinpoint the exact device location; Fire alarm control panels (FACP) and repeater panels; Smoke, heat and multi-sensor detectors
What you receive
Device schedule with locations and alarm zones; Signed commissioning and test report; Manufacturer or distributor warranty documents
AOverview

The alarm system is the first thing that knows about a fire. We agree the right scope for your facility, then supply, install, commission and test the system — and hand over clear documentation for every device and zone.

Who it's for

  • New facilities that need a complete system before opening
  • Existing facilities with outdated or incomplete systems
  • Facilities expanding or changing activity and floor areas
BScope

What the service covers

Systems

  • Conventional alarm systems for small and mid-size facilities
  • Addressable systems that pinpoint the exact device location
  • Fire alarm control panels (FACP) and repeater panels

Field devices

  • Smoke, heat and multi-sensor detectors
  • Manual call points
  • Audible and visual notification devices

Commissioning & support

  • Commissioning, testing and documented test results
  • Upgrades and extensions of existing systems
  • Hand-over into periodic maintenance
CProcess

How we deliver this service

  1. 01

    Understand the site

    Activity, floor areas, available drawings and any existing system.

  2. 02

    Define the scope

    System type, device count and alarm zones per the applicable requirements.

  3. 03

    Technical & commercial offer

    Equipment list, scope of work and a clear schedule.

  4. 04

    Installation

    Cabling, devices and panel installed to the approved layout.

  5. 05

    Commissioning & hand-over

    Every device tested, results documented, files handed over.

DDeliverables

What you receive

  • Device schedule with locations and alarm zones
  • Signed commissioning and test report
  • Manufacturer or distributor warranty documents
  • Short operator training on the control panel
ETo start

What we need from you

  • Activity type, approximate area and number of floors
  • Architectural drawings, if available
  • Photos or details of any existing system
  • Location and city
Send the details now
GFAQ

Before you ask

What is the difference between conventional and addressable systems?

A conventional system tells you which zone raised the alarm; an addressable system identifies the exact device. Conventional suits many small sites; addressable is usually preferred for larger or multi-storey buildings. The final choice depends on the applicable requirements and the size of the facility.

Can an existing system be upgraded instead of replaced?

Often, yes — depending on the system's age, device compatibility and spare-part availability. We confirm after a site visit and show you both options with their costs.

Next step

Let's review what your facility needs

Send your facility details in a few minutes. We review them and get back to you with the right scope — before any commitment.